Please refer to the following steps on how to configure 2 x NetScaler VPX Active / Passive HA in my lab
- Ensure that the first node of NetScaler VPX is configured properly
- Only configure the following in 2nd Node of NetScaler VPX
- NetScaler IP (NSIP)
- Upload the license file
Login to 2nd Node of VPX (10.1.1.210) and add the 1st node of VPX (10.1.1.150)
add ha node 1 10.1.1.150
Login to 1st Node of VPX, and add the 2nd node of VPX
add ha node 1 10.1.1.210
Enter the following command to see the HA Status
sh ha node
1st Node of VPX (10.1.1.150) is the Primary, while 2nd Node of VPX (10.1.1.210) is Secondary When i shutdown 1st Node, or manually issue the following commands to test the fail-over
force ha failover
Please confirm whether you want force-failover (Y/N)? [N]:y
Done
2nd Node of VPX is become the Primary now, and tested users can still can login to Citrix StoreFront as usual